Sensorclouds
Dashboards

Widget Types

Detailed guide to all nine dashboard widget types in Sensorclouds

Sensorclouds dashboards support nine widget types, each designed for a specific need.

Widget editors are organized into collapsible sections, so you can focus on one group of options at a time. Some editors also show a live preview.

Choosing a widget

You want to show…Use
One current numberValue Card
A number within a range, with good/bad zonesGauge
How a value changes over timeLine Chart
Totals per day/hour, or a comparison between devicesBar Chart
Several fields from several devices at onceTable
A state: on/off, open/closed, online/offlineIndicator
A switch that controls a deviceToggle
Every reading in a period, exportableTimeseries Table
A logo, map, or photoImage

Value Card

Shows a single telemetry value with a label and an optional icon. Ideal for current temperature, battery level, or any single metric.

Configuration: device, field, title, icon, unit

OptionWhat it does
Value sizeS, M (default), L, or XL. Choose XL for wall displays, S for dense dashboards
Conditional colorsColor the value by thresholds. Conditions: less than, at most, greater than, at least, equal to, between
DecimalsHow many decimal places to show
IconAn icon next to the value
TrendAn arrow comparing the value with the previous reading

Example

a cold-room temperature card at L size, blue below 2°C, green from 2–8°C, red above 8°C.

A Value Card widget

Gauge

A semicircular meter with a configurable min/max range and color zones for at-a-glance status.

Configuration: device, field, min value, max value, threshold colors, unit

Example thresholds

ZoneRangeMeaning
Green0–30Normal
Yellow30–40Warning
Red40+Critical

A Gauge widget

Line Chart

A time-series line chart that plots readings over the dashboard's time window.

Configuration: device, field(s), line color, aggregation method, time range

OptionWhat it does
Threshold linesHorizontal reference lines with custom colors
Y-axis min/maxFix the scale instead of auto-scaling
Stats stripA compact summary of the plotted values
Breach indicatorA toolbar badge when the line crosses a threshold
Sound alertsOptional beep or chime when a threshold is crossed, with a cooldown so it doesn't repeat constantly
Line styleLine width, fill area and opacity, and whether to connect gaps

A Line Chart widget

Bar Chart

Compares values across time buckets, or across devices and metrics.

Modes

ModeUse it toExample
Time-bucketedAggregate one field into buckets over the windowDaily water use for the last 7 days
Categorical / groupedCompare the same metric across devices, or several metrics on one deviceToday's energy per building

Options: bucket interval (for example 1d), Compare by axis, custom groups, per-series color and label, horizontal or vertical layout, sort order (highest or lowest first), bar labels, threshold coloring, and corner radius. Missing buckets are left as gaps, never silently filled.

A Bar Chart widget

Table

Shows the latest values for several fields across one or more devices.

Configuration: devices (multiple), fields, column labels

Example

one row per pump, with columns for pressure, flow, and temperature.

A Table widget

Indicator

A status light for discrete or connectivity states. It shows a colored state with an optional label, icon, and "last updated" age.

Modes

ModeHow the state is chosenExample
Value matchRules map a field's value to a state, color, label, and icon0 = Closed (grey), 1 = Open (green)
StalenessBased on how long since the last reading: fresh, stale, or offlineA gateway that should report every minute

Options: show or hide the label, icon, and last-updated time; make a chosen state blink; set a default state for when there's no data yet.

An Indicator widget

Toggle

An interactive on/off switch that sends a command to a device. It supports a confirmation step and custom labels, and the switch rolls back if the command fails.

Configuration: device, command name, on/off values, labels, icons, confirmation, command timeout

Layout: classic or modern style

Toggles are the only widgets Crew can interact with. A toggle sends exactly the command it was set up with, and nothing else.

Turn on confirmation for anything that could cause harm if switched by accident, such as pumps, heaters, or door locks.

What the toggle shows:

StateMeaning
Syncing...The command was sent, and the toggle is waiting for the device to acknowledge it. The switch is locked meanwhile
ConfirmedThe device acknowledged the command
Failed + RetryThe device reported a failure. The switch returns to its previous position
Timeout + RetryThe device didn't acknowledge in time. The switch returns to its previous position
Offline (greyed out)The device is offline, so the toggle can't be used
Configuration Error + Edit SettingsThe widget is missing its device or command

A Toggle widget

Timeseries Table

A paginated table of historical readings with sortable timestamps and configurable decimal precision. Supports CSV export.

Configuration: device, fields, page size, decimal places

CSV export depends on your plan. If the Export CSV button isn't visible, ask your administrator.

A Timeseries Table widget

Image

New in 1.5.0. Shows a picture on the dashboard, such as your company logo, a floor plan, or a site photo.

Configuration: title (optional), image, display fit, alt text, background color, size

Display fitBehaviorBest for
Fit (default)The whole image is visible inside the widgetLogos
FillThe image covers the widget and is cropped if neededPhotos
StretchThe image is stretched to the widget's exact shapeBackgrounds

Images come from your workspace's shared image library. Upload once, reuse on any dashboard. See Image Widget & Library.

Troubleshooting

Widget shows…CauseFix
Configure a data source to display …The widget has no device or field yetOpen the widget's settings and pick a device and field
Waiting for device data...The device hasn't sent this field in the selected rangeCheck the device's Live Data. Make sure the field name matches the decoded payload exactly
The field isn't in the widget's listThe device hasn't sent it yetSend at least one message containing the field. See Field Discovery
A chart or gauge stays empty for a text valueThe field arrives as a string, such as "21.5"Return a number from the device or decoder
A toggle shows TimeoutThe device didn't acknowledge the commandCheck that the device subscribes to its command topic and replies on its ACK topic. See Command Lifecycle
A toggle shows FailedThe device's acknowledgment wasn't a successThe device must reply with "status": "ok" or "success": true
A toggle is greyed outThe device is offlineBring the device online. See Device Status

Next Steps

On this page