Sensorclouds
Telemetry

Field Discovery

How Sensorclouds learns your devices' fields automatically, with no schema to define

You don't define a schema in Sensorclouds. Whenever a decoded message contains a key the platform hasn't seen for that device, it's registered as a new field automatically, and it's ready to use in widgets, alarms, and reports.

How it works

A device sends {"temperature": 21.5, "door": true}.

Sensorclouds checks the device's known fields.

Any new key is registered with its type, a first seen time, and a sample value.

On later messages, the field's last seen time is updated.

Detected typeFrom values like
number21.5, 0, -3
string"OPEN", "v2.1.0"
booleantrue, false

Where fields are used

  • Widget configuration: the field dropdowns list discovered fields
  • Alarm rules: choose the field to watch
  • Reports: choose fields to summarize
  • Latest Telemetry on the device's Overview tab

Numeric fields work with charts, gauges, and alarms. If a value arrives as a string ("21.5"), fix the device or decoder to send a number.

Troubleshooting

ProblemFix
A new field isn't in the widget's listThe device must send it at least once. Check Live Data
Two fields for one value (temp and temperature)The device or decoder renamed the key. Keep names stable
No fields at allThe profile's codec is NONE. Switch to CUSTOM

Next Steps

On this page