Telemetry
Field Discovery
How Sensorclouds learns your devices' fields automatically, with no schema to define
You don't define a schema in Sensorclouds. Whenever a decoded message contains a key the platform hasn't seen for that device, it's registered as a new field automatically, and it's ready to use in widgets, alarms, and reports.
How it works
A device sends {"temperature": 21.5, "door": true}.
Sensorclouds checks the device's known fields.
Any new key is registered with its type, a first seen time, and a sample value.
On later messages, the field's last seen time is updated.
| Detected type | From values like |
|---|---|
number | 21.5, 0, -3 |
string | "OPEN", "v2.1.0" |
boolean | true, false |
Where fields are used
- Widget configuration: the field dropdowns list discovered fields
- Alarm rules: choose the field to watch
- Reports: choose fields to summarize
- Latest Telemetry on the device's Overview tab
Numeric fields work with charts, gauges, and alarms. If a value arrives as a string
("21.5"), fix the device or decoder to send a number.
Troubleshooting
| Problem | Fix |
|---|---|
| A new field isn't in the widget's list | The device must send it at least once. Check Live Data |
Two fields for one value (temp and temperature) | The device or decoder renamed the key. Keep names stable |
| No fields at all | The profile's codec is NONE. Switch to CUSTOM |