Payload Decoder
Write JavaScript that turns your device's raw payload into named fields
A payload decoder is a short JavaScript function that turns what your device sends (JSON
text, bytes, or hex) into named fields like temperature and battery. Sensorclouds runs it on
every message from every device using the profile.
Decoders live on the profile's Payload Formatter tab, with a code editor and a tester.

How it works
A device publishes a message.
If it's a hex string, Sensorclouds converts it to bytes (see Hex payloads).
Your decoder receives the payload as an array of byte values (numbers 0–255).
Your decoder returns an object of fields.
The fields are stored, and dashboards, alarms, and integrations use them.
Function formats
Define one of these functions. Sensorclouds uses the first one it finds, in this order:
| Format | Signature | Return |
|---|---|---|
| TTN v3 (recommended) | decodeUplink(input), where input.bytes is the byte array and input.fPort is the port | { data: { …fields } } |
| Legacy | Decoder(bytes, port) | { …fields } |
| Simple | decode(bytes, port) | { …fields } |
bytes is a plain array of numbers, not a Node.js Buffer. Methods like
readInt16BE() or toString('utf8') don't exist. Combine bytes yourself, as shown below.
JSON payloads
If your device sends JSON such as {"temperature": 21.5, "humidity": 48}, use this decoder:
function decodeUplink(input) {
var text = String.fromCharCode.apply(null, input.bytes);
return { data: JSON.parse(text) };
}Keep JSON flat, with numbers, strings, and booleans at the top level. Each key becomes a field.
Binary payloads
Example: a sensor sends 3 bytes: temperature × 100 as a 16-bit big-endian integer, then humidity in percent.
function decodeUplink(input) {
var b = input.bytes;
var raw = (b[0] << 8) | b[1];
if (raw & 0x8000) raw -= 0x10000; // signed 16-bit
return {
data: {
temperature: raw / 100, // 0x09D5 → 25.17
humidity: b[2] // 0x3C → 60
}
};
}Test payload: 0x09D53C → { "temperature": 25.17, "humidity": 60 }
Common byte patterns
| You need | Code |
|---|---|
| Unsigned 16-bit, big-endian | (b[i] << 8) | b[i+1] |
| Signed 16-bit, big-endian | v = (b[i] << 8) | b[i+1]; if (v & 0x8000) v -= 0x10000; |
| Unsigned 16-bit, little-endian | b[i] | (b[i+1] << 8) |
| Unsigned 32-bit, big-endian | ((b[i] << 24) >>> 0) + (b[i+1] << 16) + (b[i+2] << 8) + b[i+3] |
| A single bit (flag) | (b[i] & 0x04) !== 0 |
| Text | String.fromCharCode.apply(null, b) |
Hex payloads
On CUSTOM profiles, a payload that is a hex string is converted to bytes before your decoder runs, if it:
- starts with
0x(for example0x09D53C), or - is 8 or more hex characters (for example
09D53C1A),
and has an even number of hex digits.
Short hex strings without 0x, such as 09D53C (6 characters), are not
converted. Your decoder receives the characters 0, 9, D, and so on as text. Add the 0x
prefix on the device to be safe.
Timestamps and buffered readings
Two optional keys in your decoder's output have special meaning:
| Key | Effect |
|---|---|
timestamp | The reading's time: Unix seconds, Unix milliseconds, or an ISO 8601 string. It's used as the reading time when the profile uses DEVICE time, or when it's more than 30 seconds old |
backfill | true marks the reading as buffered data sent late |
Both keys are removed before storing, so they don't become fields. See Sending Telemetry Data.
Starting point
When you switch a profile's Codec Type to CUSTOM, the Decoder Script editor starts
with a sample decode(input) function. It reads two 16-bit values from the first four bytes and
returns them as temperature and humidity (each divided by 10). Replace it with your own
decoder.
For ready-to-use decoders (JSON, binary readings, bit flags, text formats, several sensors in one message, and readings with their own timestamps), see Writing Payload Decoders.
Testing your decoder
Always test with a real payload before devices use the profile.
On the Payload Formatter tab, find Test Decoder.
Enter a payload in Sample Payload, as hex (for example 0x0A1B2C3D) or base64.
Click Run Test.
Check the result:
- Decoding Successful shows the Decoded Output, the Execution Time, the Memory Used, and any Console Logs your decoder printed.
- Decoding Failed shows the error message.
When the output is right, click Save Configuration. The tester runs the script in the editor, so you can test changes before saving them.
The tester accepts hex or base64 only. To test a JSON decoder, convert the
JSON to base64 first. For example, {"temperature":21.5} is eyJ0ZW1wZXJhdHVyZSI6MjEuNX0=.
Pasting JSON text directly gives Unexpected token errors even when the decoder is correct.
Copy real payloads from Live Data (open an event to see its raw payload). Test the edge cases too: negative values, the maximum range, and short or missing bytes.
What happens when a decoder fails
If your decoder throws an error or times out, the message isn't stored. It appears in Live Data as Decode failed with the error message. Fix the decoder, and new messages are stored again.
Limits
| Limit | Value |
|---|---|
| Decoder size | 40 KB |
| Run time per message | 5 seconds |
| Memory | 128 MB |
| Network, file, and process access | None |
Troubleshooting
| Live Data shows… | Cause | Fix |
|---|---|---|
| Decode failed - readInt16BE is not a function | Buffer methods used | Combine bytes manually, as in the table above |
| Decode failed - No decoder function found | No decodeUplink, Decoder, or decode defined | Rename your function |
| Decode failed - Unexpected token | JSON decoder received non-JSON | Check what the device actually sends |
| The tester says Unexpected token, but the device works | JSON text was pasted into Sample Payload | Paste the JSON as base64 instead (see Testing your decoder) |
| The tester says Invalid payload format | The sample isn't valid hex or base64 | Check for stray characters, or re-encode the payload |
| Uplink received, but no fields | Codec is NONE, or the decoder returned nothing | Switch to CUSTOM and return fields |
| Values look random | Byte order or offsets are wrong | Test with a known payload and compare |